Model
|
EGX-600
|
EGX-400
|
| Table
type |
T
slot
|
| Table
size |
610
(W) x 407 (D) mm (24 (W) x 16 (D) in.)
|
407
(W) x 305 (D) mm (16 (W) x 12 (D) in.)
|
| Cutting
area |
610
(X) x 407 (Y) x 42.5 (Z) mm (24 (X) x 16 (Y) x 1-5/8 (Z)
in.)
|
407
(X) x 305 (Y) x 42.5 (Z) mm (16 (X) x 12 (Y) x 1-5/8 (Z)
in.)
|
Loadableworkpiece
thickness |
Maximum
40 mm (1-9/16 in.)
|
| XYZ-axis
motor |
AC
servo motors (DAC-FFP), 3-axis simultaneous control
|
| Feed
rate |
XY-axis:
0.5, 1 to 100 mm/s (0.02 in./s, 0.039 to 3.9 in./s) Z-axis:
0.5, 1 to 50 mm/s (0.02 in./s, 0.039 to 1.9 in./s)
|
| Acceleration |
0.1
G, 0.05 G
|
| Software
resolution |
0.01
mm/step (0.00039 in./step)
|
| Mechanical
resolution |
XY-axis:
0.003 mm/step (0.00012 in./step) Z-axis: 0.0025 mm/step
(0.000098 in./step)
|
| Spindle
motor |
DC
brushless motor, Maximum 72 W
|
| Spindle
speed |
8,000
to 30,000 rpm
|
| Tool
chuck |
Cutter
holder (4.36 mm) and collet
|
| Positioning
Accuracy |
±
0.1 % of distance traveled or ± 0.1 mm (± 0.004 in.), whichever
is greater (no-load operation)
|
| Repeatability |
0.05
mm (0.002 in.) or less
|
| Interface |
Parallel
connector (Centronics-compliant), serial connector (RS-232C-compliant),
Memory card slot (Compliance
with Multi Media Card), expansion connector 1, expansion
connector 2
|
| Buffer
memory |
2MB
(replot buffer: 1.9MB)
|
| Instruction
system |
RML-1
(mode 1, mode 2)
|
| Power
supply |
AC
117 V, 230 V, 240 V ± 10 %, 50/60 Hz
|
| Power
consumption |
3.5
A at 117 V, 1.6 A at 230 V, 1.6 A at 240 V
|
| Acoustic
noise level |
No-load
operation: 75 dB (A) or less standby: 45 dB (A) or less
(According to ISO 7779)
|
| Dimensions
(main unit) |
995
(W) x 820 (D) x 521 (H) mm (39-3/16 (W) x 32-5/16 (D) x
20-1/2 (H) in.)
|
795 (W)
x 719 (D) x 521 (H) mm (31-5/16 (W) x 28-5/16 (D) x 20-1/2
(H) in.)
|
| Weight
(main unit) |
64
kg (141 lb.)T slot
|
51
kg (112 lb.)
|
| Operating
environment |
Temperature:
5 to 40°C (41 to 104°F) humidity: 35 to 80 % (no condensation)
|
| Accessories |
Operation
panel: 1, Operation-panel connector cable: 1, Power cord:
1, Depth regulator nose unit: 1, Solid collet : 1,
Clamps : 4, Roland Software Package CD-ROM : 1, User's Manual:
1Benchtop Engravers EGX-600/400 SPECIFICATIONS
|